Minimum fire resistance REI60 from both sides with E30 Sa fire doors
Minimum fire resistance REI 120 from accommodation side and REI60 from inside the shaft with E60 Sa fire doors
NOTES:
1.Outlets from a fire main should be located in the firefighting lobby or, in the case of a shaft serving flats, in the firefighting stairway (see Diagram b).
2.Smoke control should be provided in accordance with BS9999 or, where the firefighting shaft only serves flats, the provisions for smoke control given in paragraph 3.49 may be followed instead.
3.A firefighting lift is required if the building has a floor more than 18m above, or more than 10m below, fire service vehicle access level.
4.This diagram is only to illustrate the basic components and is not meant to represent the only acceptable layout. The firefighting shaft should be constructed generally in accordance with section 6 of BS 9999.
5.For the minimum fire resistance of lift doors see Table C1.
See paras 15.2,15.8 and 15.9

Item Type: Image
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: firefighting shaft, firefighting lobby, firefighting lift, firefighting lift, firefighting stair, fire resistance, fire risk assessment, protected shaft, fire resisting (Fire resistance), fire safety - volume 2: buildings other than dwellings. 2019 edition - for use in england
Subjects: K Law > The Building Regulations 2010 > B5: Access and facilities for the fire service
T Technology > TH Building construction > Building standards > fire safety - volume 1: dwellings. 2019 edition - for use in england > Section 15: Access to buildings for firefighting personnel – flats
T Technology > TH Building construction > Building standards
Depositing User: Umesh Pardale
Date Deposited: 11 May 2020 06:00
Last Modified: 13 Oct 2021 19:41
URI: https://eprints.buildvoc.co.uk/id/eprint/949

Actions (login required)

View Item
View Item