Common escape routes

Department for Communities and Local Government, (2019) Common escape routes. In: Approved Document B: Fire Safety - Volume 1: Dwellings. 2019 ed. Section 3: Means of escape – flats, 1 (3.32). RIBA Publishing Publication, London, p. 30. ISBN 9781859469156

Full text not available from this repository.

Abstract

Escape route travel distances should comply with Table 3.1.

Item Type: Book Section
Additional Information: mml-maui-text-analytics-keywords
Uncontrolled Keywords: travel distance, travel distance, escape route, should, alternative escape routes, measurement, escape lighting, access room, means of escape, purpose group
Subjects: T Technology > TH Building construction > Building standards > fire safety - volume 1: dwellings. 2019 edition - for use in england > Section 3: Means of escape – flats
K Law > The Building Regulations 2010 > B1: Means of warning and escape
T Technology > TH Building construction > Building standards
Date Deposited: 01 Feb 2020 08:08
Last Modified: 13 Oct 2021 19:40
URI: https://eprints.buildvoc.co.uk/id/eprint/248

Actions (login required)

View Item
View Item